every protocol.almost every vendor.
If your equipment speaks BACnet, Modbus, SNMP, M-Bus, KNX or LoRaWAN — we work with it. We have pre-built templates for the most common vendors in Mexican facilities + a process for adding anything that's not. Every new client expands the library.
supported, native or via bridge
of equipment covered
in the public library
with canonical template ready
what we speak.
Real compatibility is by protocol, not by vendor. Any equipment that speaks one of these we can integrate — even if we don't have its specific vendor in the library yet.
BACnet/IP
Ethernet BACnet — the most common protocol in modern BMS. Full AI/AO/BI/BO/AV/BV object reads.
BACnet MS/TP
Serial BACnet — legacy equipment + RTUs. Supported via on-site BACnet/IP ↔ MS/TP router.
Modbus TCP
UPS, generators, switchgear. Vendor- and family-specific Modbus maps.
Modbus RTU
Legacy HVAC and UPS. Tunneled via industrial gateway to the cloud.
SNMP v1/v2c/v3
UPS, PDUs, network gear. MIBs templated for Eaton, APC, Vertiv, Schneider, Raritan.
M-Bus
Energy + water meters. Periodic AMR-style meter reads.
KNX
European building automation. Less common in MX but supported.
LoRaWAN
Far-away equipment without its own network. LoRaWAN converter tunnels to the central gateway.
oBIX (Niagara)
Niagara N4 extension. Direct read from Niagara stations that don't expose BACnet/IP.
Proprietary protocols
Vendors with closed stacks. Custom decoders via Node-RED / Python; first-customer engineering absorbed.
OPC UA
Industrial/SCADA. Via an intermediate Kepware-style gateway. Custom quote.
BMS platforms.
The integrated systems that coordinate your equipment
Tridium Niagara
TEMPLATEDCoexistence: we read from your existing Niagara without replacing it. Tridium-certified team.
Honeywell EBI
TEMPLATEDJohnson Controls Metasys
TEMPLATEDSchneider EcoStruxure
CUSTOMSiemens Desigo
CUSTOMDistech Controls
CUSTOMUPS + power.
Uninterruptible power + automatic transfer
Eaton
TEMPLATEDDeepest vendor in our library. Our MX-distributor referral is our primary channel.
APC (Schneider)
TEMPLATEDVertiv (Liebert)
TEMPLATEDSchneider Electric
TEMPLATEDABB
CUSTOMHVAC + climate control.
Building HVAC controllers and equipment
Honeywell
TEMPLATEDJohnson Controls
TEMPLATEDCarrier
TEMPLATEDTrane
CUSTOMDaikin
CUSTOMMitsubishi Electric
CUSTOMCRAC / CRAH.
Computer-room cooling
Vertiv Liebert
TEMPLATEDStulz
CUSTOMSchneider Uniflair
CUSTOMAiredale
PLANNEDPDUs (rack power).
Rack-level power distribution
APC
TEMPLATEDEaton
TEMPLATEDRaritan
TEMPLATEDServer Technology (Schneider)
CUSTOMGeist (Vertiv)
CUSTOMchillers.
Chilled water plants
Carrier
TEMPLATEDTrane
CUSTOMYork (Johnson Controls)
CUSTOMDaikin Applied
CUSTOMgenerators.
Electrical backup + automatic transfer
Generac
TEMPLATEDOften requires a LoRaWAN bridge when the generator is far from the gateway.
Cummins
TEMPLATEDKohler
CUSTOMCaterpillar
CUSTOMsensors + I/O.
Environmental sensors + energy meters + generic I/O
LoRaWAN sensors
TEMPLATEDFor equipment / spaces without a network. Bridged via LoRaWAN converter to the gateway.
Veris Industries
TEMPLATEDSenva / ACI
CUSTOMSenseware
PLANNEDevery new client makes it bigger.
When we integrate a vendor or family that wasn't there before, the template is permanent. The next client with that same equipment onboards faster. The library is a growing asset — not an integration fee.
your equipment is already in the library
Normal onboarding. Template configuration for your specific site (IPs, points, alerts). Operating in a week or less.
your equipment is new to us
First-customer engineering absorbed by AstreaBMS. We build the template, validate it with you, add it to the permanent library. Benefits all future customers with the same equipment.
the limits, said out loud.
Vaultis is read-only by design. We don't write to your BMS. If you need automated real-time control (PID loops, active demand response), that's your BMS's job — Niagara, Metasys, EBI. Vaultis lives on top, observes, alerts. Doesn't act.
Optimized for facilities (data centers, buildings, plants with critical MEP). Not for production lines. If you need industrial process control with millisecond loops, we're not the tool.
When the security equipment exposes BACnet or Modbus, we integrate it like any other vendor. We don't run VMS, don't manage physical access credentials, don't do camera control.
If your equipment is 100% analog (no comm card, no SNMP, no Modbus), we can't poll it directly. Solution: we install external sensors (current, temperature) that connect via LoRaWAN. Works — but requires physical installation.
bring your equipment list to the demo.
Send us your inventory or specific models. In 24–48 hours we tell you: what's in the library, what needs engineering, what we can't do. No implementation surprises.